1 Technical data
Temperature range -40°C to +90°C
Permissible operating temperature at the conductor +120°C
Nominal voltage AC 1,0/1,0 kV DC 1,5/1,5 kV
Test voltage AC 6,5 kV
Minimum bending radius fixed installation 5x outer Ø
2 Cable structure
Tinned copper conductor, fine wire acc. to DIN VDE 0295 cl.5 / IEC 60228 cl.5
1. Core insulation: special cross-linked compound, black
2. Core insulation: special cross-linked compound, black
Braiding of stainless steel single V2A (rodent protection)
3 Properties
Double-insulated
Complies protection class II
UV-resistant
Ozone resistant
Tests
Halogen-free acc. to EN 50267, IEC 60754
Flame retardant acc. to IEC 60332-1-2
Smoke density acc. to IEC 61034
Weathering/UV-resistance acc. to EN 50289-4-17 Method A
Ozon resistance acc. to EN 50396 Clause 8.1.3 Methode B
Approvals
EN 50618 ,TÜV Rheinland 2 PfG 1990/05.12 ,TÜV R60115689